Project
Workload
Import RVTools, enter totals by hand, or both
Drop RVTools exports here or click to choose (.xlsx / .xlsm, several files at once).
Files are read in your browser and never uploaded.
Files are read in your browser and never uploaded.
Amber cells are overridden by hand. Storage basis is set under Storage.
Host type
All hosts in a cluster use one typeVCF deployment profile
VCF Installer default profiles (VCF 9.1)Sizing policy
Every cluster gets its own HA spare host(s). Minimum hosts per cluster are set automatically: management (or the shared cluster) 4 for HA profiles, 3 for Simple on vSAN, 2 on r7i; workload clusters 3 on vSAN (6 for manual RAID-6), 2 on r7i. No memory overcommit. Past the per-instance limit, the calculator adds EVS instances.
Storage
Guest used = space used inside the VMs (RVTools vPartition); allocated = provisioned disk size (vDisk).
Memory tiering
NVMe as a second memory tier (VCF 9.x)Settings
Settings and workload totals as text, to save or send to someone.
Sources and assumptions
- Host types and VCF versions: AWS EVS User Guide, "Supported VCF versions and instance types" (r7i added Nov 2026; diskless types need external principal storage). EC2 instance specifications for cores and memory.
- Hosts per instance: 32 (AWS, May 2026; service quota increase needed above the default).
- Management resources: Broadcom VCF 9.1 "VCF Fleet Sizing Models" (first and additional instance totals per profile). Minimum hosts: VCF 9.x docs – Simple 2 (external) or 3 (vSAN); HA 4 (NSX Manager anti-affinity).
- Memory tiering: AWS "Increase your cluster density with Memory Tiering in Amazon EVS" – default tier 1:1, drives leave vSAN, keep active memory under ~50% of DRAM.
- Licensing: Broadcom VCF SPD – per-core, 16-core minimum per CPU. vSAN capacity is covered by the 1 TiB per core included with VCF: every EVS host type's raw NVMe is below its core entitlement.
- On i-type hosts the local drives are always vSAN ESA (principal storage) minus memory-tier drives; FSxN is a supplemental datastore for a share of workload storage, and VCF management stays on vSAN. r7i uses FSxN for everything.
- vSAN usable = raw × (1 − reserve) × compression ÷ protection factor per cluster. Auto policy: RAID-6 4+2 at 6+ hosts, RAID-5 2+1 at 3–5 (both 1.5); manual RAID-5 adaptive 4+1 = 1.25 at 6+; RAID-1 = 2. Spare hosts' drives aren't counted toward capacity. Workload is spread evenly across instances. Growth is one uplift for the contract term. Data last verified 23 Nov 2026.